‘Investigation into the role of various factors during Flasking and Packing of Heat Cure Acrylic Resin, resulting in occlusal descrepancies in processed Complete Dentures’.

JAY VIKRAM, ASHISH CHOUDHARY, HITEN KALRA, ABHILASHA VIKRAM

Abstract


Aim-The purpose of this study is to evaluate the displacement of artificial teeth in the invested mould in different orientations of the occlusal plane and evaluation and comparison of the displacement of teeth in waxed dentures after packing & processing of complete dentures.
Materials & Method - 27 mandibular edentulous cast were selected on which waxed up dentures were prepared with six metal tubes inserted. These served as reference points for measurements. Radiographs were taken for each waxed up denture during all the stages of flasking and processing. The scanned radiographs were subjected to AutoCAD programme, to evaluate the positional variation of metal tubes, signifying the shifting of the teeth during flasking and processing of the dentures. The measurements obtained were subjected to statistical analysis. The thickness of the ‘flash’ produced during packing of the three different resins was also noted & compared.
Result- There was no statistical significant deviation in the dimensional discrepancies for 0, 20 &30 degrees orientation of occlusal plane; however, dentures made with Lucitone had minimum thickness of ‘flash’ & showed least dimensional discrepancies amongst the three heat cured resins used.
Conclusion- The use of more plastic heat cure acrylic resin material exhibit least average thickness of ‘flash’, thus minimizing the occlusal discrepancies during processing of complete dentures. 


Keywords


Occlusal Discrepancies;Complete Denture;Heat Cure Acrylic Resin;Processing of Complete Denture

Full Text:

pdf

References


Grant A.A. ‘Effect of the investment procedure on tooth movement’. J .Prosthet. Dent., 1962; 12: 1053-1059.

Tucker M.K., Freeman B.J. ‘The effect of investing material on processing changes in complete dentures’. J. Prosthet. Dent., 1971; 25: 206-210.

Perlowski S.A. ‘Investment changes during flasking as a factor of complete denture malocclusion’. J. Prosthet. Dent., 1953; 3: 360-369.

Zakhari.K.N. ‘Relationship of investing medium to occlusal changes and vertical opening during construction’. J. Prosthet. Dent.,1976; 36: 501-508.

Mainieri.E.T. Boone M.E., Potter R.H. ‘Tooth movement and dimensional change of denture base material using two investment methods’. J. Prosthet. Dent., 1980; 44: 368-373.

Dukes B.S, Fields H.Jr., Morris J.C., Jewell A. ‘A comparative study of changes in vertical dimensions of occlusion using different investment mediums’. J. Prosthet. Dent. , 1983; 49: 568-571.

Maler D.B. ‘In articulation of complete dentures processed by compression molding technique’. J. Prosthet. Dent., 1951; 1: 551-559.

Lerner H., Pfeiffer K.R. ‘Minimum vertical occlusal changes in cured acrylic resin dentures’ J. Prosthet. Dent., 1964; 14: 294-297.

Woelfel J.B., Paffenbarger G.C., Sweeney W.T. ‘Dimensional changes occurring in artificial dentures’. Int. Dent. J 1959; 9: 451-457.

Lam. R.V . ‘Disorientation of tooth to cast relationship as a result of flaskingprocedures’. J. Prosthet. Dent., 1965;15: 651-661.

Shippee R.W. ‘Control of increase vertical dimension compression molded denture’. J. Prosthet. Dent., 1961; 11: 1080-1085.

Rudd K.D. ‘Processing complete denture without tooth movement’. D.C.N.A. 1964;675-691.

Pera F.L E. ‘Avoiding the increase in vertical dimension of denture in processing’. J. Prosthet. Dent., 1968; 19: 369-379.

Honorato V .A. ‘Double-processing technique for complete dentures’. J. Prosthet. Dent., 1969; 22: 500-505.


Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.

line
Index Copernicus Index CopernicusGoogle Scholar
System Developed By Stanford University Arizona State University Simon Fraser University Canadian Centre For Studies In Publishing University of British Columbia - Faculty of Education
line
W3C XHTML v1.0 Verified W3C verified Valid CSS v2.1 PHP5 Enabled Copyscape - DO NOT COPY Made On Mac Apache Enabled MySQL Powered
Published by Celesta Software Pvt Ltd